A complete digital workflow with options at every stage: guided surgery, scanners, photogrammetry, libraries and prosthetic components, each made to fit the next.
01Planning
Start with the End in Mind
Implant position, soft tissue profile and restorative needs are analysed together before design begins. MODE libraries bring the implant and the M-Guide guided surgery kit into your planning software.
RAPIDEYE intraoral scanners capture the arch, and MODE scanbodies transfer the position and angulation of each implant, from a single implant to an edentulous arch.
The restoration is designed on the selected MODE component, considering function, occlusal relationships and adjacent teeth. Ti-Base and Multi-Unit libraries are ready for your CAD software.
The prosthesis is manufactured from the digital data. Digital analogs position the implants in the model; Ti-Bases, digital copings and bar connections join the restoration to the implant.
The restoration is placed on the prosthetic components and the connection fit is verified. Occlusion and intraoral adaptation are evaluated, and the treatment is completed.
The same digital workflow scales from one crown to a complete arch. Select a case to see its components and steps.
Ti-Base Abutment Series · Engaged
One Implant, One Crown
Engaged Ti-Bases in Standard, Long and Angled Flex options, with the scanbody and digital analog for the same connection.
Standard Ti-Base4 mm
Long Ti-Base7 mm
Flex Ti-Baseup to 20°
Scanbody
Digital Analog
1Soft Tissue Scanning
Soft tissue around the implant is digitally scanned to help define the restorative margins. This supports esthetic integration and more accurate planning of the emergence profile.
2Single Implant Scanning
The scanbody is placed on the implant to transfer its position and connection data to the digital environment: the essential data for a single implant case.
3Selection of the Ti-Base
Each case requirement is evaluated to select the ideal component from the Long, Standard or Flex Ti-Base range, for an optimized emergence profile.
4Case Analysis and Planning
Implant position, soft tissue profile and restoration needs are analysed together before digital design, increasing predictability throughout the treatment.
5Digital Crown and Bridge Design
The restoration is designed on the selected prosthetic component, considering function, occlusal relationships and adjacent tooth alignment.
6Clinical Try-In and Initial Evaluation
The restoration is placed on the prosthetic components and the connection fit is verified, before final intraoral adjustment.
7Final Adjustment and Delivery
Occlusion, connection fit and intraoral adaptation are evaluated. After any necessary adjustments, the restoration is finalized.
Ti-Base Non-Engaged · Multi-Unit
Several Implants, One Restoration
Non-engaged Ti-Bases and Multi-Unit abutments for bridges, with scanning components that transfer the position and angulation of every implant.
Non-Engaged Ti-BaseStandard, Long, Flex
Multi-Unit Abutmentstraight
Angled Multi-Unit17° and 30°
Scanbody
Multi-Unit Scanbody
1Soft Tissue Scanning
Soft tissue around the implant is digitally scanned to help define the restorative margins. This supports esthetic integration and more accurate planning of the emergence profile.
2Scanning in Multi-Implant Cases
Scanning components transfer the position and angulation of every implant. The resulting data enables final restorations without trials in multi-implant cases.
3Selection of the Ti-Base
Each case requirement is evaluated to select the ideal component from the Long, Standard or Flex Ti-Base range, for an optimized emergence profile.
4Case Analysis and Planning
Implant position, soft tissue profile and restoration needs are analysed together before digital design, increasing predictability throughout the treatment.
5Digital Crown and Bridge Design
The restoration is designed on the selected prosthetic component, considering function, occlusal relationships and adjacent tooth alignment.
6Clinical Try-In and Initial Evaluation
The restoration is placed on the prosthetic components and the connection fit is verified, before final intraoral adjustment.
7Final Adjustment and Delivery
Occlusion, connection fit and intraoral adaptation are evaluated. After any necessary adjustments, the restoration is finalized.
Multi-Unit Abutment Series
A Full Arch, Planned for Passive Fit
Straight, 17° and 30° Multi-Unit abutments adapt to implant position. The Multi Scanning Kit and Reverse Scanbody are made for edentulous cases.
Multi-Unit Abutmentstraight
Angled Multi-Unit17° and 30°
Multi-Unit Scanbody
Multi Scanning Kit
Reverse Scanbody
Digital Coping
1Case Evaluation and Abutment Selection
Implant positions are evaluated according to the treatment plan, and the appropriate Multi-Unit abutments are selected.
2Soft Tissue Scan
Soft tissue around the implant is digitally captured to support accurate planning of the restorative margins.
3Scanning of Multi-Unit Scanbodies
Scanbodies are placed to transfer the position and angulation data of the implants to the digital environment.
4Coping Connection
Supports passive-fit restorations by providing a stable foundation for monolithic zirconia and temporary restorations.
5I-Bar Connection
An alternative connection option to meet different clinical requirements and support restorative flexibility.
6Prosthetic Seating and Fit
The restoration is seated, and connection integrity and intraoral fit are then evaluated.
Ti-Base Abutment Series
For single-unit and bridge restorations made with CAD/CAM systems. Engaged and non-engaged, for NP and RP platforms.
Standard · 4 mm
Long · 7 mm
Flex · 4.3 mm
1
Square-Cut Post
A prep-form geometry with flat surfaces for anti-rotational seating and a homogeneous cement gap.
2
Angled Screw Channel
Flex Ti-Base supports angulations of up to 20°. The Flex Screw and Flex Driver are designed for stable torque transfer.
3
Conical Connection
A precise conical connection and a robust connection architecture.
Standard Ti-Base
Ideal for restorations with a 4 mm crown connection height. Suitable for single-unit and multi-unit restorations compatible with CAD/CAM systems.
Long Ti-Base New
The 7 mm option is intended for deeply placed implants or restorations requiring greater vertical height.
Flex Ti-Base New
Optimized for angled screw channels of up to 20°, offering improved esthetics and greater flexibility in challenging cases.
Flex Screw New
Developed for Ti-Base restorations, with a specialized head design compatible with angled screw channels.
Flex Driver New
Supports angulations of up to 20° for easier access to angled screw channels, with stable and reliable torque transfer.
Every Ti-Base is available for NP and RP platforms, Engaged and Non-Engaged, in two heights: 0.7 and 2.5 mm (Flex: 1.0 and 2.5 mm). The screw head and driver interface help reduce the risk of slipping or stripping during clinical use.
Multi-Unit Abutment Series
For screw-retained bridge and full-arch restorations, with a transgingival contour optimized for natural gingival anatomy and full compatibility with global CAD/CAM libraries and intraoral scanners.
Straight
17° angled
30° angled
1
Universal Prosthetic Connection
Supports a wide range of screw-retained restorations, with a seamless 360° platform for stability and passive fit.
2
Long Conical Connection
Stable seating and sealing through a 1.44 mm implant-abutment conical contact surface.
3
Octagonal Connection
More indexing options than trilobe, square or hexagonal designs, helping improve passive fit in multi-unit restorations.
Standard Multi-Unit
NP in heights of 1.5, 2.5 and 3.5 mm. RP in heights of 1.5, 2.5, 3.5 and 4.5 mm.
17° Angled Multi-Unit New
NP and RP in heights of 1.5, 2.5 and 3.5 mm.
30° Angled Multi-Unit New
NP and RP in heights of 2.5, 3.5 and 4.5 mm.
Multi-Unit Digital Coping
A 4 mm coping that gives monolithic zirconia and temporary restorations a stable foundation.
Gingival height options adapt to different gingival levels, supporting soft tissue management and a controlled emergence profile. The series offers a passive fit tolerance of up to 30° for angled implant placements, with an M1.4 prosthetic screw in a fully enclosed channel.
Full-Arch Precision Scanning Solutions
Intraoral scanners rely on reference points in the soft-tissue topography. In edentulous cases, capturing them from soft tissue can slow scanning and increase the risk of cross-arch deviation.
Multi-Unit Scanbody
Designed for accurate digital registration of both straight and angled Multi-Unit abutments. It is manufactured from titanium, and its sandblasted surface helps reduce reflections and supports faster digital matching.
Multi Scanning Kit New
Connected to the Multi-Units, the kit gives the scanner rigid reference points across the arch. Scan efficiency is improved, cross-arch deviation is minimized and excessive overlapping scan data is reduced.
Reverse Scanbody New
Designed for edentulous cases on the reverse scanning principle: implant positions are transferred to the digital environment with high accuracy, directly through the temporary restoration.
Digital Workflow with the Reverse Scanbody
The clinically approved temporary prosthesis becomes the reference for the final one.
1Referencing the Temporary Prosthesis
A temporary prosthesis with clinically verified function and fit is used as a reference: the foundation for accurate and reliable recording of implant positions.
2Connecting the Reverse Scanbodies
Reverse Scanbodies are attached to the temporary prosthesis to read the implant positions, so implant coordinates are transferred with high accuracy.
3Intraoral Scanning in a Clinical Setting
With the scanbodies attached, the temporary prosthesis is transferred to the digital environment with an intraoral scanner, reducing the number of patient visits.
4Digital Matching
Through the scan data, the Reverse Scanbodies are matched within the software to clarify implant positions for restorative planning.
5Digital Design of the Final Prosthesis
The final restoration is designed using the approved temporary prosthesis as a reference, preserving functional and esthetic data while accelerating design.
6Production and Passive Fit
The final prosthesis is manufactured from the data obtained through the Reverse Scanbody protocol, supporting passive fit in clinical application.
Photogrammetry-Assisted Scanning Systems
The MODE digital workflow operates in full compatibility with photogrammetry-based intraoral and extraoral scanning technologies.
Intraoral
Photogrammetry compatibility for precision full-arch scanning, inside the mouth.
Compatibility with global devices and library support
Compatibility with Multi-Unit photogrammetry scan bodies
Guaranteed precision results within seconds
Eliminates RPT risks
Extraoral
Photogrammetry compatibility for precision full-arch scanning, with an extraoral camera.
Compatibility with global devices and library support
Compatibility with Multi-Unit photogrammetry scan bodies
Guaranteed precision results within seconds
Eliminates RPT risks
Compatible with global extraoral precision scanning systems such as Imetric, Oxo and others.
For full-arch photogrammetry within the ecosystem, see the RAPIDEYE Orion Kit. Imetric®, Oxo® and other trademarks mentioned on this page are the property of their respective owners.
Compatible with Your Digital Workflow
Alongside the RAPIDEYE scanners in the ecosystem, MODE components and libraries work with common scanners, planning and design software and stability measurement devices.
This notice is provided by Mode Medikal San. ve Tic. Ltd. Şti. (“Mode Medikal”), as data controller, to inform visitors of modeimplant.com under Turkish Personal Data Protection Law No. 6698 (“KVKK”).
The name, email address, phone number and message you share through our contact forms,
The email address you give when you sign up for our newsletter,
The messages you write to the help assistant on the site,
Technical information needed to run the site (IP address, browser and device details, language preference) and, if you allow analytics cookies, information about your visit.
3. Why We Process It
To answer your requests and questions and to contact you,
With your consent, to send newsletters about our products, events and announcements,
To keep the website secure and working properly,
With your consent, to measure how the site is used and improve it,
To meet our legal obligations.
4. Legal Grounds
We process your personal data on the grounds set out in Article 5(2) of the KVKK: where it is directly related to entering into or performing a contract, where it is needed to meet a legal obligation, and where it is necessary for our legitimate interests, provided this does not harm your fundamental rights and freedoms. Newsletters and analytics and marketing cookies are based only on your explicit consent.
5. Sharing Your Data
Limited to the purposes above, your personal data may be shared with the business partners that provide our website hosting and email services, and with authorised public authorities when they request it. If you allow analytics cookies, information about your visit may be processed by Google on servers outside Türkiye as part of the Google Analytics service. Any transfer is made in line with Articles 8 and 9 of the KVKK.
6. How Long We Keep It
We keep personal data for as long as the purpose requires and for the periods set by law. Your newsletter sign-up is kept until you unsubscribe. After that, the data is deleted, destroyed or anonymised.
7. Your Rights
Under Article 11 of the KVKK, you have the right to: learn whether your personal data is processed and request information about it; learn the purpose of processing and whether it is used for that purpose; know the third parties in Türkiye or abroad it is shared with; ask for incomplete or incorrect data to be corrected; ask for it to be deleted or destroyed under the conditions set by law; ask for these steps to be notified to third parties it was shared with; object to a result against you arising solely from automated analysis; and claim compensation if you suffer damage from unlawful processing.
You can send your request by email to info@modeimplant.com or in writing to the address above. We will respond free of charge within 30 days at the latest.
COOKIE POLICY
What is a cookie?
Cookies are small text files that a website saves in your browser. Our site also uses your browser’s local storage to remember your choices.
Cookies we use
Essential cookies: needed for the site to work and cannot be switched off. They remember your language (pll_language) and your cookie choices.
Analytics cookies: used only if you allow them. Google Analytics 4 (_ga, _ga_*) helps us measure which pages are visited and how the site is used.
Marketing cookies: used only if you allow them, to show you more relevant content and advertising.
Videos: YouTube or Vimeo videos in the patient guide do not load until you press play. Once you play a video, that platform may use its own cookies.
Managing your choices
You can allow or refuse analytics and marketing cookies in the cookie preferences window that opens on your first visit. To change your choices, delete this site’s cookies and site data in your browser settings; the preferences window will open again on your next visit. If you block essential cookies, parts of the site may not work properly.
Last updated: 17 November 2026
? Cookie Preferences
We use cookies to enhance your experience
We use essential cookies for site functionality and optional cookies to improve your experience, analyze site usage, and assist in our marketing efforts.