Mode Implant
Clinicalretrospective

Retrospective evaluation of marginal bone loss and survival rates of single piece dental implants with bendable abutments

This retrospective study followed 100 one-piece PROVO implants in 20 patients for one year. All implants survived (100%), and mean marginal bone loss was 0.22 mm.Şencan et al. · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95 · DOI 10.5281/zenodo.7945001 · CC BY 4.0

2022
(226.82 KB)
Clinicalretrospective

The effect of different attachment types on marginal bone loss in implant overdenture prosthesis: A retrospective study

MODE Level implants supporting overdentures were followed radiographically for nine years. Marginal bone loss did not differ significantly between Ball and Locator attachments.Çapkat et al. · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95 · DOI 10.5281/zenodo.7953298 · CC BY 4.0

2022
(234.89 KB)
Laboratorymechanical testing

Dynamic and static load performance of dental biomaterial systems with conical implant-abutment connections

An independent laboratory compared three implant systems with 11° conical connections. MODE implants reached the highest fracture loads under both static and dynamic-plus-static loading.Basgil et al. · Bio-Medical Materials and Engineering 2020 · DOI 10.3233/bme-206008

2020
(doi.org)
Clinicalretrospective

The Effect of Implant Position, Thread Design and Tilting on Marginal Bone Resorption in Tilted Implant System

Full-arch cases were restored on tilted and axial MODE Level and Rapid implants (All-on-4 type). After one year, total marginal bone loss was 0.2994 mm in the mandible and 0.3992 mm in the maxilla, with no significant difference between tilted and axial implants.Aktürk et al. · Eurasian Journal of Oral and Maxillofacial Surgery 2024;3(4):120-126

2024
(miacademy.com.tr)
Computer simulation (FEA)

Biomechanical comparison of various implant inclinations and abutment types in a bendable implant system

This BMC Oral Health study modelled All-on-4 restorations on PROVO implants. Cement-retained prostheses spread stress more favourably, especially with greater posterior implant angulation.Özyetim et al. · BMC Oral Health 2025 · DOI 10.1186/s12903-025-06610-1 · CC BY 4.0

2025
(2.15 MB)
Laboratoryex vivo

Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study

Five clinicians with different levels of experience placed 300 MODE Rapid implants in bovine rib bone. Primary stability did not differ significantly between them, apart from one Periotest result for the inexperienced clinician.Geçkili et al. · Medicina Oral, Patología Oral y Cirugía Bucal 2019;24(2):e254-e259 · DOI 10.4317/medoral.22733

2019
(doi.org)
Clinicalretrospective

Retrospective evaluation of marginal bone loss of dental implants with prostheses bonded to Ti-base abutments

MODE implants were restored with Ti-base abutments. One year after loading, mean marginal bone loss was 0.0118 mm for Rapid and 0.0456 mm for Level, and every parameter examined met implant success criteria.Kaya et al. · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95, pp. 10-14 (pages per SSCP bibliography) · DOI 10.5281/zenodo.7953328 · CC BY 4.0

2022
(223.79 KB)
Clinicalretrospective

The effect of crown-implant ratio and opposing dentition on marginal bone loss: A 2-year retrospective study

The study followed 133 single-crown MODE implants for two years. Crown-to-implant ratio had no significant effect on marginal bone loss (p = 0.560), and neither did the type of opposing dentition.Burduroğlu et al. · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95 · DOI 10.5281/zenodo.7953316 · CC BY 4.0

2022
(342.23 KB)
Clinicalprospective (pilot)

Evaluation of marginal bone loss in dental implants with different thread structure: Pilot study

This prospective pilot study followed 41 MODE implants for one year. Thread design (aggressive Rapid or regular Level) had no significant relationship with marginal bone loss.Nalbantoğlu et al. · Türk Dişhekimliği Dergisi (TDD), April 2023, No. 96

2023
(miacademy.com.tr)
Clinicalretrospective (pilot)

Comparison of marginal bone loss in single crowns with Ti-base and cemented abutments: A retrospective pilot study

Over two years, single crowns on MODE Ti-base abutments showed mean marginal bone loss of 0.027 mm, against 0.314 mm for cemented abutments. The difference was not statistically significant.Burduroğlu et al. · Türk Dişhekimliği Dergisi (TDD), April 2023, No. 96

2023
(miacademy.com.tr)
Computer simulation (FEA)

Influence of Framework Material on Biomechanical Performance of an All-on-4 Prosthesis Supported by Bendable Monoblock Implants

A finite element analysis compared five framework materials for an All-on-4 prosthesis on four PROVO-S implants. Glass-fibre-reinforced composite came out as a possible alternative to metal frameworks.Özyetim et al. · Bioengineering 2026;13(5):581 · DOI 10.3390/bioengineering13050581 · CC BY 4.0

2026
(20.27 MB)
Clinicalcase report

Loading cases with permanent prosthetic structures by using monoblock bendable implants in 72 hours in periodontal bone loss

These case reports describe patients with periodontal bone loss who received MODE PROVO implants and permanent zirconia prostheses within 72 hours.Şencan et al. · Türk Dişhekimliği Dergisi (TDD), April 2023, No. 96

2023
(miacademy.com.tr)
Clinicalcase report

Using monoblock bendable implants instead of two-pieces implant in treating difficult cases

Two-piece implants were hard to place in this patient's narrow maxilla, so MODE PROVO monoblock bendable implants were used there, with MODE Level implants in the mandible.Şencan et al. · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95 · DOI 10.5281/zenodo.7953376 · CC BY 4.0

2022
(576.35 KB)
Laboratoryin vitro

Evaluation of the fracture resistance and failure types of different CAD-CAM ceramic crowns supported by angled titanium abutments

In an independent study in the Journal of Prosthodontics, CAD-CAM crowns were tested on 72 MODE titanium abutments angled at 0°, 15° and 25°. Monolithic zirconia on straight abutments had the highest fracture resistance.Yüksel et al. · Journal of Prosthodontics (accepted Aug 2022; online 2022, issue 2023) · DOI 10.1111/jopr.13596

2022
(doi.org)
Laboratoryin vitro

Effect of different surface treatments on retention of cement-retained, implant-supported crowns

This International Journal of Prosthodontics study tested six surface treatments on MODE titanium abutments. Sandblasting gave the highest crown retention, at 828.5 N.Özyetim et al. · International Journal of Prosthodontics 2023;36(1):49-58 (Crossref issued 2021 - online first) · DOI 10.11607/ijp.6602

2023
(doi.org)
Laboratoryin vitro

Effect of different surface treatments on surface wettability of titanium abutments

A laboratory study measured surface wettability after five different surface treatments on 60 MODE titanium abutments.Özyetim et al. · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95 · DOI 10.5281/zenodo.7953368 · CC BY 4.0

2022
(273.61 KB)
Laboratoryin vitro

Investigation of the Wetting Properties of Thalassemia Patients' Blood Samples on Grade 5 Titanium Implant Surfaces: A Pilot Study

Blood from patients with beta-thalassaemia major wetted MODE Grade 5 titanium surfaces in the same way as blood from healthy people, with no significant difference.Temelci et al. · Biomimetics 2023;8(1):25 · DOI 10.3390/biomimetics8010025 · CC BY 4.0

2023
(1.94 MB)
Laboratoryin vitro

Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations

This Dental Materials Journal study used MODE implants and multi-unit abutments to compare full-arch impression techniques. Polyvinyl siloxane ether was less accurate than polyether, PVS and digital impressions.Çopuroğlu et al. · Dental Materials Journal (advance publication 2025; Crossref issue year 2026) · DOI 10.4012/dmj.2025-150 · CC BY 4.0

2025
(2.60 MB)
Clinicalcase report

The effect of prosthetic options on clinical success of implant supported prosthesis - Case report

A fully edentulous patient received a hybrid prosthesis on eight MODE Rapid implants in the maxilla and a ball-retained overdenture on two MODE Level implants in the mandible.Kaya · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95, pp. 42-46 (pages per SSCP) · DOI 10.5281/zenodo.7953393 · CC BY 4.0

2022
(549.89 KB)
Clinicalcase report

All-on-4 implant treatment and immediate loading protocol in the patient with severe periodontal destruction

A patient with severe periodontal destruction was treated with All-on-4 and immediate loading on tilted MODE Rapid implants.Atasoy · Türk Dişhekimliği Dergisi (TDD), July 2022, No. 95 · DOI 10.5281/zenodo.7953405 · CC BY 4.0

2022
(700.51 KB)
Clinicalcase report

Quattrofix option in lower anterior mandible: A case report

This case uses the Quattrofix option. Four MODE Level implants in the anterior mandible, two axial and two tilted, support an immediately loaded fixed prosthesis.Bilgen et al. · Türk Dişhekimliği Dergisi (TDD), April 2023, No. 96, pp. 22-26

2023
(miacademy.com.tr)
Clinicalcase report

Fixed prosthetic rehabilitation of complete edentulism in severely resorbed crests with subperiosteal implants and quattrofix: A case report

Severely resorbed crests were restored with subperiosteal implants and the Quattrofix approach, using four MODE Level implants and MODE multi-unit abutments.Emirmahmutoğlu et al. · Türk Dişhekimliği Dergisi (TDD), April 2024, No. 97, pp. 42-47 · DOI 10.69786/turkdishekder.2024.4

2024
(doi.org)
Clinicalcase report

The Partial All-on-4 Approach for Patients with Limited Posterior Bone Volume and Periodontally Compromised Teeth in the Maxilla: A Case Report

A patient with limited posterior bone and periodontally compromised teeth was treated with a partial All-on-4 approach in the maxilla, using MODE Rapid implants.Zenginer et al. · EC Dental Science 24.12 (2025): 01-06

2025
(miacademy.com.tr)
Clinicalcase report

İmplant Destekli Overdenture Protezlerde Sağlanamayan Bilateral Balanslı Artikülasyon ve Klinik Çözümü: İki Olgu Sunumu

This paper reports two overdenture cases on MODE ball abutments, with satisfying pink and white aesthetic results.Türkay et al. · Selcuk Dental Journal 2023 · DOI 10.15311/selcukdentj.1176017

2023
(doi.org)
Laboratoryin vitro

Influence of Scan Body Geometry, Implant Angulation, and Interimplant Distance on the Accuracy of Maxillary Full-Arch Digital Implant Impressions

An independent study compared full-arch digital scan accuracy using scan bodies from three implant systems, one of them MODE. The highest deviations at specific positions came from the other two systems.Ekin et al. · Medical Science Monitor 2026 · DOI 10.12659/msm.953734

2026
(doi.org)

Publications are listed for scientific information. Laboratory and computer-simulation results do not represent clinical outcomes.